Victron Isolation Transformers Description:
Indispensable in professional marine energy systems. It prevents electrolytic corrosion and above all serves as a device to guarantee a safe electric system. Toroidal wound technology for quietness and high efficiency. Soft start circuitry will ensure that the shore circuit breaker will not trip when plugged in.
Safety is taken for granted in case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore-side supply to the metal parts of the boat will result in galvanic corrosion (see below). Bringing only the live and neutral wire on board results in an unsafe situation because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.
Parameter | 2000 Watt | 3600 Watt | 3600 Watt Auto 115/230 V | 7000 Watt |
---|---|---|---|---|
INPUT | ||||
Input | 115 or 230 V | 115 or 230 V | 115 / 230 V Automatic switching | 230 V |
Output | 115 or 230 V | 115 or 230 V | 115 or 230 V | 230 V |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Rating | 17 / 8,5 A | 32 / 16 A | 32 / 16 A | 32 A |
Soft start | Yes | |||
Transformer type | Toroidal (low noise, low weight) | |||
Input circuit breaker | Yes | |||
ENCLOSURE | ||||
Common Characteristics | Material: aluminium (blue RAL 5012), Protection category: IP 21 | |||
Weight | 10 Kg | 23 Kg | 24 Kg | 31 Kg |
Dimensions (h x w x d), mm | 375 x 214 x 110 | 362 x 258 x 218 |